Apc Ups Rs 600 User Manual

Smart-UPS 5000 VA 208/230 Vac Tower/Rack-Mount 5U User Manual 1 Introduction About this UPS The American Power Conversion (APC®) Uninterruptible Power Supply (UPS) provides protection for electronic equipment from utility power blackouts, brownouts, sags and surges. Amazon.com: apc back-ups 600 - APC. Skip to main content. Try Prime EN Hello, Sign in Account & Lists Sign in Account & Lists Orders Try Prime Cart.

Advertising

Back-UPS NS 600

User’s Guide

1

2

3

Connect Battery

Equipment

Power On and
Install Software

990-2437A Copyright © 2007 American Power Conversion Corp.

All other trademarks are property of their respective owners.

Surge Protection

These outlets provide full-time protection from surges even if the
Back-UPS NS is switched OFF. Plug your printer, fax machine,
scanner, or other peripherals that do not need battery power into
these outlets.

Battery Back-up plus Surge Protection

These outlets are powered whenever the Back-UPS NS is
switched ON. During a power outage or other utility problems
(brownouts, over-voltages), these outlets will be powered for a
limited time by the Back-UPS NS. Plug your computer,
monitor, CD-ROM drive and one other data-sensitive device
such as an external disk or tape drive, or Home Phoneline
Networking Association (HPNA) device into these outlets.

Press the ON/OFF switch to power the unit
ON.

A single short beep and the green “Power”
indicator confirms the Back-UPS NS is on and
ready to provide protection.

The Back-UPS NS should charge for at least 16
hours to ensure sufficient runtime. The unit is
being charged whenever it is connected to utility
power, whether the unit is turned ON or OFF.

If the red Building Wiring Fault indicator (located
on the end near the power cord) is lit, your
building wiring presents a shock hazard that
should be corrected by a qualified electrician.

Install the PowerChute

®

Personal

Edition

software

Place the PowerChute Personal Edition CD-
ROM into your computer and follow the
installation instructions on the screen.

w

w

w.apc.com

®

APC, Back-UPS and PowerChute are registered trademarks of American Power Conversion Corp.

Status

Visual Indicators

Audible Indicators

Alarm Terminates

When

On Line - UPS is supplying conditioned
utility power to the load.

Power LED - ON

None

n/a

On Battery - UPS is supplying battery
power to the load connected to the
Battery outlets.

Power LED - ON
(off during beep)

Beeping 4 times
every 30 seconds

UPS transfers back to
On Line operation, or
when UPS is turned
off.

Low Battery Warning - UPS is supplying
battery power to the load connected to
the Battery outlets and the battery is near
exhaustion.

Power LED - Flashing

Rapid beeping (half-
second intervals)

UPS transfers back to
On Line operation, or
when UPS is turned
off.

Replace Battery - Battery needs to be
checked and/or replaced, or battery is not
connected.

Power LED - Flashing

Constant tone

UPS turned off with
the power switch.

Overload Shutdown - During On Battery
operation a battery power supplied outlet
overload was detected.

Power LED - OFF

Constant tone

UPS turned off with
the power switch.

Sleep Mode - During On Battery
operation the battery power has been
completely exhausted and the UPS is
waiting for utility power to return to
normal.

Power LED - OFF

Beeping once every
4 seconds

Utility power is
restored, or if utility
power is not restored
within 32 seconds, or
the UPS is turned off.

Building Wiring Fault - Your building
wiring presents a shock hazard that
should be corrected by a licensed
electrician.

Building Wiring Fault
LED (red) - ON

None

UPS is unplugged, or
plugged into a
properly wired outlet.

Status Indicators

Power

Circuit

Breaker

AC Line

Cord

Building Wiring

Fault Indicator

UPS Power

Indicator

Power

Switch

®

See the Troubleshooting section for additional assistance.

For safety, the Back-UPS NS is shipped with one battery wire disconnected. The UPS will not operate until the wire is connected to the touch-safe
battery terminal. NOTE: Small sparks may occur during battery connection. This is normal.

Turn the Back-UPS NS over and press in the
two release tabs. Slide the plastic battery
cover off the unit.

Insert the battery back into the compartment.
Slide the plastic battery cover in place until the
two tabs lock into place.

Connect the battery wire firmly to
the battery terminal.

1

2

3

Plastic Battery

Cover

Release Tabs

Apc ups 650 user manual

Battery Wire

Apc

Battery Terminal

Connect

Connect Modem / Phone / DSL / Fax / HPNA to Surge Protection

The Back-UPS protects a single line (2-wire) phone (including Digital Subscriber Line -
DSL), Home Phoneline Networking Association (HPNA) type equipment, modem, or
fax machines from surges when connected through the UPS as shown below.

Place the Back-UPS NS to avoid:

- Direct sunlight
- Excessive heat
- Excessive humidity or contact with fluids

Plug the Back-UPS NS power cord directly into a wall outlet; not a surge
protector or power strip.

Connect Computer Cable

The supplied cable and software provide automatic file saving and shutdown of the
operating system in the case of a sustained power outage.

Connect the cable to the Data Port of the Back-UPS NS. Connect the other end of the
cable to the USB port on your computer. The software will automatically find the USB
Port of your computer.

DSL / MODEM /

WALL

TO COMPUTER USB PORT

FROM WALL JACK

DATALINE OUTPUT TO DSL,

MODEM, PHONE,

OUTLET

DATA PORT

FAX

Power

Battery Backup plus Surge Protection

Surge Protection

The Back-UPS NS indicates operating status
using a combination of visual and audible
indicators.

Advertising
Popular Brands
Popular manuals

Page 2: Contact information, Limited warranty, Transfer voltage and sensitivity adjustment

Advertising

SPECIFICATIONS

Item

Specification

On-line Input Voltage Range
(default settings)

83 - 147 Vac (RS model)
83 - 139 Vac (XS model)

Automatic Voltage Regulation (AVR)

+12% (XS model) +12% (RS model)

On-line Frequency Range

47 - 63 Hz (autosensing)

On-battery Waveshape

Stepped Sine Wave

Maximum Load

1000 VA - 600 W 1500 VA - 865 W

Typical Recharge Time

8 Hours

Operating Temperature

32

o

to 104

o

F

0

o

to 40

o

C

Storage Temperature

23

o

to 113

o

F

-5

o

to 45

o

C

Operating / Storage Relative Humidity

0 to 95% non-condensing

Apc Back-ups Rs 800 Manual

Size (H x W x D)

14.6 x 3.4 x 13.1 inch

37.1 x 8.6 x 33.3 cm

Weight

1000 VA 22 lbs (10 kg)
1500 VA 25 lbs (11 kg)

Shipping Weight

1000 VA 23 lbs (11 kg)

1500 VA 26 lbs (12 kg)

EMI Classification

FCC / DOC Class B Certified

On Battery Run-Time

See http://www.apc.com/product

TROUBLESHOOTING

Problem

Possible Cause

Corrective Action

Back-UPS will not switch on.

Back-UPS not connected to AC power source.

Ensure the Back-UPS is securely connected to an AC outlet.

Back-UPS circuit breaker “tripped”.

Disconnect non-essential equipment from the Back-UPS. Reset
(push in) the rear panel circuit breaker. Switch on the Back-UPS
and plug in devices one at a time. If the circuit breaker trips
again, disconnect the device that caused the breaker to trip.

Utility input voltage quality is out of range.

Consider adjusting the transfer voltage and sensitivity. See
Transfer Voltage and Sensitivity Adjustment.

Back-UPS does not power
essential equipment during an
outage.

Equipment plugged into a Surge Only outlet.

Unplug device from 'Surge Only' outlet and move to a 'Battery
Backup' outlet.

Back-UPS operates on battery
although utility power exists.

Back-UPS circuit breaker “tripped”.

Disconnect non-essential equipment from the Back-UPS. Reset
(push in) the rear panel circuit breaker. Switch the Back-UPS on
and plug equipment in one-at-a-time. If the circuit breaker trips
again, disconnect the device that caused the breaker to trip.

Utility input voltage quality is out of range.

Consider adjusting the transfer voltage and sensitivity. See
Transfer Voltage and Sensitivity Adjustment.

Back-UPS does not provide
expected backup time.

Back-UPS is heavily loaded.

Unplug non-essential equipment (printers, scanners, etc) from
the Battery Backup outlets and plug into 'Surge Only' outlets.

Back-UPS battery cartridge is discharged due to
recent power outage and has not had time to
recharge.

Charge the battery cartridge for 8 hours. Back-UPS runtime is
reduced until the battery cartridge is fully charged.

Battery has reached the end of its life.

Replace battery cartridge (see Order Replacement Battery
Cartridge
).

Red Replace Battery indicator is
flashing. Green On Line indicator
is on.

Internal battery cartridge is not connected.

Connect battery cartridge (see Connect Battery Cartridge).

Red Replace Battery indicator is
on.

Battery has reached the end of its life.

Replace the battery cartridge (see OrderReplacement Battery
Cartridge
).

Red Overload indicator is on or
flashing.

Connected equipment is drawing more power than
the Back-UPS can provide.

Move one or more equipment power plugs from Battery Backup
outlets to Surge Only outlets.

Green On Line indicator is on and
all other front panel indicators are
flashing.

Internal UPS fault.

Contact APC Technical Support (see Contact Information).

Battery

Cartridge

REPLACE BATTERY CARTRIDGE

ORDER REPLACEMENT BATTERY CARTRIDGE

The battery cartridge typically lasts 3-6 years, shorter if subjected to frequent outages or elevated temperatures. Order part number RBC33.
Please recycle spent battery cartridges.

990-2163A Copyright © 2007 American Power Conversion All rights reserved.

APC and Back-UPS are registered trademarks of American Power Conversion.

All other trademarks are the property of their respective owners.

SERVICE

If the Back-UPS arrived damaged, notify the carrier.

If the Back-UPS requires service, do not return it to the dealer. The following
steps should be taken:

1.

Consult the Troubleshooting section to eliminate common problems.

2.

If the problem persists, go to http://www.apc.com/support/.

3.

If the problem still persists, contact APC Technical Support.

• Have the Back-UPS model number, serial number and date of purchase

available. Be prepared to troubleshoot the problem with an APC Technical
Support representative. If this is not successful, APC will issue a Return
Merchandise Authorization (RMA) number and a shipping address.

CONTACT INFORMATION

Technical Support

http://www.apc.com/support

Internet

http://www.apc.com

USA / Canada

1.800.800.4272

Mexico

292.0253 / 292.0255

Brazil

0800.12.72.1

Worldwide

+1.401.789.5735

Ups

LIMITED WARRANTY

The standard warranty is two (2) years from the date of purchase. APC’s standard
procedure is to replace the original unit with a factory reconditioned unit. Customers
who must have the original unit back due to the assignment of asset tags and set
depreciation schedules must declare such a need at first contact with an APC Technical
Support representative. APC will ship the replacement unit once the defective unit has
been received by the repair department, or cross-ship upon the receipt of a valid credit
card number. The customer pays for shipping the unit to APC. APC pays ground
freight transportation costs to ship the replacement unit to the customer.

In situations where the Back-UPS or connected equipment appears too sensitive to
input voltage, it may be necessary to adjust the transfer voltage. This is a simple task
requiring use of the front panel pushbutton. To adjust the transfer voltage, proceed as
follows:
1. Plug the Back-UPS into the utility power source. The Back-UPS will be in a

Standby Mode (no indicators lit).

2. Press the front panel pushbutton fully inward for 10 seconds. All indicators on the

Back-UPS will flash to acknowledge going into Programming Mode.

3. The Back-UPS will then indicate its current Sensitivity Setting, as shown in the

following table.

4. To select the Low Sensitivity setting, press the pushbutton until the yellow

indicator is flashing.

5. To select the Medium Sensitivity setting, press the pushbutton until the yellow

and red indicators (second and third from the top) are flashing.

6. To select the High Sensitivity setting, press the pushbutton until yellow and both

red indicators (bottom three) are flashing.

7. To exit without changing the Sensitivity Setting, press the pushbutton until the

green indicator is flashing.

8. Once in Programming Mode, if the pushbutton is not pressed within 5 seconds,

the Back-UPS will exit Programming Mode; all indicators will extinguish.

Indicators

Flashing

Sensitivity

Setting

Input Voltage

Range

(for utility

operation)

RS Models

Input Voltage

Range

(for utility

operation)

Apc Back-ups Rs 600 Manual

XS Models

Use When

1

(yellow)

Low

78 - 150 Vac

78 - 142 Vac

Input voltage is

extremely low or high.

Not recommended for

computer loads.

2

(yellow,

and red)

Medium

(factory

default)

83 - 147 Vac

83 - 139 Vac

Back-UPS frequently

goes On Battery.

3

(yellow,
red, and

red)

High

88 - 144 Vac

88 - 136 Vac

Connected equipment is

sensitive to voltage

fluctuations .

TRANSFER VOLTAGE AND SENSITIVITY
ADJUSTMENT

Notice: This device complies with part 68 and 15 of the FCC rules.Operation is subject
to the following two conditions: (1) This device may not cause harmful interference.
(2) This device must accept any interference received, including interference that may
cause undesired operation.

Apc Back Ups Rs 1100 Manual

On the bottom of this equipment is a label that contains, among other information, the
FCC registration number and ringer equivalence number (REN) for this equipment. If
requested, this information must be provided to the telephone company.